FPGA Market

Obsolete device

XC2S400E replacement options

The AMD Xilinx XC2S400E has been discontinued by the manufacturer. There are two ways forward, and for most people reading this the first one is the answer: keep the design and source the part. Changing device means a board revision, so it is only worth it if you are redesigning anyway.

What the manufacturer says

AMD Xilinx's discontinuation notice lists no direct replacement for all 27 XC2S400E parts it covers. Where the manufacturer offers nothing equivalent, the remaining supply is the only way to keep the board unchanged.

From the manufacturer's discontinuation notice: Product Discontinuation Notice: Spartan-IIE, Virtex-E, Virtex-EM, Virtex-II, EasyPath Virt

1. Keep the design — source the XC2S400E

Discontinued parts are still traded. We hold 17 orderable XC2S400E parts — send the exact code and quantity and we'll come back with stock and pricing, including date-code and traceability requirements.

Request a quote
Part numberPackagePinsSpeedTemperature
XC2S400E-6FG456CFG4564566Commercial
XC2S400E-6FG456IFG4564566Industrial
XC2S400E-7FG456CFG4564567Commercial
XC2S400E-6FG676CFG6766766Commercial
XC2S400E-6FG676IFG6766766Industrial
XC2S400E-7FG676CFG6766767Commercial
XC2S400E-6FGG456CFGG4564566Commercial
XC2S400E-6FGG456IFGG4564566Industrial
XC2S400E-7FGG456CFGG4564567Commercial
XC2S400E-6FGG676CFGG6766766Commercial
XC2S400E-6FGG676IFGG6766766Industrial
XC2S400E-7FGG676CFGG6766767Commercial
XC2S400E-6FT256CFT2562566Commercial
XC2S400E-6FT256IFT2562566Industrial
XC2S400E-6FTG256CFTG2562566Commercial
XC2S400E-6FTG256IFTG2562566Industrial

All 17 XC2S400E parts

A different package or speed grade of the same device is the closest thing to a like-for-like change: the silicon is the same, so only the footprint or timing differs. It still needs checking against your board.

2. Redesigning? Current devices of similar capacity

AMD Xilinx devices still in production with comparable logic capacity, closest first. These are a shortlist to evaluate, not equivalents: none of them is pin-compatible with the XC2S400E, and none is recommended by the manufacturer as its successor. We select them by capacity from the data on this site.

DeviceFamilyLogic cellsvs XC2S400EBlock RAMDSPParts
XC2S400ESpartan-II10,800The original160 Kb17
XCSU10PSpartan UltraScale+10,938About the same logic cells1,728 Kb245
XC7S15Spartan-712,8001.2× the logic cells360 Kb2018
XC7A12TArtix-712,8001.2× the logic cells720 Kb4014
XA7A12TArtix-712,8001.2× the logic cells720 Kb2
XA7S15Spartan-712,8001.2× the logic cells360 Kb202
XC7A15TArtix-716,6401.5× the logic cells900 Kb4531

What to check before changing device

  • Footprint and pinout

    Ball count, pitch and pin assignment all differ between families. A new device means a new layout.

  • I/O voltages and banks

    Supported I/O standards, bank voltages and the number of banks change between generations.

  • Core and I/O supplies

    Newer devices usually run a lower core voltage and need a different power tree.

  • Configuration

    Flash type, configuration mode and boot timing are family-specific.

  • Tools and IP

    The design has to be rebuilt in the current toolchain, and IP cores may need replacing or re-licensing.

  • Temperature and lifetime

    Check the grade you need exists, and how long the new family is expected to stay in production.

Where a design cannot be revised — certified equipment, long-life industrial and defence builds — sourcing the original is normally the cheaper route, even at obsolete pricing.